- Lead Design Assurance Engineer (LDAE) for EGL2 cable works as defined in BP/SR188.
- Fulfil the role of LDAE role including design review, hazard review, attending design, hazard review meetings and assurance of design deliverable.
- Agree Design & Hazard review meeting strategy with Lead Contractor Design Approval Engineer (LCDAE) for design deliverables.
- Proactively coordinate with the LCDAE to provide an approved design.
- The role also requires supporting other work/design packages for EGL2 as required for cable interfaces.
- Provide ad-hoc and independent assistance/assessment for escalated/complex technical items.
- Participate in cable discipline team discussions
- Provide guidance/mentoring to junior engineers.
- Lead as required and participate in regular meetings, both internally with EGL2 and other consultants and stakeholders who may be involved.
- Coordinate and ensure design interfaces with 400kV AC substation & 525kV HVDC converter station for end-to-end connection.
- Provide weekly and monthly progress update to EGL2 engineering manager.
- Review and accept ITP/Pre-qualification test/Type Test/QA documents.
- Coordinate with cable contractor’s (HVDC (Prysmian) & HVAC (HEBAM (NKT)) to get documentation and achieve NG Type Registration & SSEN-T equipment approval.
- Attend monthly progress meeting in Europe (Milan, Italy).
- Use EGL2 document management system for project documentation.
- UK Industry standard D
- Design Assurance Engineer (preferably Lead Design Assurance Engineer) authorisation (TP141).
- 525kV HVDC and 400kV AC cable system design experience.
- NG and SSEN projects design delivery experience.
- Experience of pre-qualification testing, type testing and factory acceptance testing.
- Knowledge and understanding of UK industry standards, design handbook, and processes
- BP188/SR188 Design Management
- SR106, SR183 Type Registration Equipment procedural requirements
- TS 2.01 Substations
- TS 3.05.16 Extruded cables for HVDC voltages up to 800kV
- TS 3.05.07 Installation requirements for HV power cable systems
- SCT36 Cable systems
- NGET DH30 Capital design handbook – Overhead line, Cables and Substation – Design, Supply and Installation interfacing generic division of responsibilities/
- Knowledge and understanding of SSEN-T standards, technical approval, and processes.
- SP-NET-CAB-500 Underground cable specification for transmission rated AC voltage
- PR-NET-ENG-509 Technical approval process within SSEN Transmission
- CDM 2015
- ESQCR
- CIGRE TB 852 Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to and including 800kV
- Electra 189 Recommendations for tests of power transmission DC cables for a rated voltage up to 800kV
- IEC 62067 Power cables with extruded insulation and their accessories for rated voltages above 150kV (Um=170kV) upto 500kV (Um=550kV) test methods and requirements
- IEC 61914 Cable cleats for electrical installations
- ENA TS 09-02 Specification for the supply, delivery and installation of power cables with operating voltages in the range 33kV to 400kV and associated auxiliary cables
- ENA TS 12-24- Technical specification for plastic ducts for buried electric cables
- ENA TS C 55 - Insulated sheath power cable systems
- Full time Staff or Contingent Worker Contract options available.
- Competitive Salary, plus discretionary bonus